Açıklama

INTERNAL COMPONENTS
———————————

● 2 Thermo – Differential Alarms (Infrared)

● Smoke Alarm

● Manual Alarm

● Main Alarm Connected to Fire Station

● Keystore

● Indoor and Outdoor Horn

● Optical Alarm Warning (with LEDs)

● 4 Resistor Terminators

● Fire Alarm Center:

Key-Operating Switch for Locking Fire Alarm to Master Alarm

Inputs: LINE 1 / LINE 2 / Door Position / Switch Position / Answer

Outputs: ALARM OUTPUT / Relay K1 / 12 V External / Door Opener

Indicators (with LEDs): Operation ON, Operation OFF / ALARM / FAULT / FAULT OFF,

ALARM for LINE 1 and LINE 2/ Locked Key Store / Key Store Location

Buttons: BUZZER OFF / RESET /OFF, ON for LINE 1 and LINE 2

Simulation: Power Failure and Battery Loss

EXPERIMENTS THAT CAN BE DONE AND THE SUBJECTS THAT CAN BE EXPLAINED FROM THE EXPERIMENT BOOK;
—————————————————————- —————————————————————- ———

● VdS/TSE Rules

● Fire Alarm System Components

●Smoke Alarms

● EXPERIMENTS THAT CAN BE DONE AND THE SUBJECTS THAT CAN BE EXPLAINED FROM THE EXPERIMENT BOOK;

● Flame Detection

● Non-Automatic Fire Alarms

● Network Alarm

● Thermal Difference Alarms

● Optical Smoke Alarms

● Button Fire Alarm

● Fire Service Private Warehouse

● Fire Gas Alarm

● Temperature Alarm

● Thermal Alarms

Technical Data

——————-

Mains connection

– Mains voltage: 230 V AC / 115 V AC (110 V AC)

50 … 60 Hz; approx. 10VA

Thermo-differential alarm (infrared)

– Operating voltage: 12 V DC

Optical smoke alarm

– Operating voltage: 12V

hand alarm

– The glass pane is simulated by a sliding plexiglass door.

– The alarm is indicated by a red LED.

– The alarm is triggered by a pushbutton.

– Operating voltage: 12 V

Main alarm

– The alarm is indicated by a red LED.

– Main alarm at rest, green LED alight

– The alarm is triggered by a pushbutton.

– Alarm to fire station additionally indicated by a red LED

– Operating voltage: 12 V

Alarm center:

– Voltage output: 12 V DC / 0.2 A

All inputs and outputs are wired by 2 mm jacks.

Mechanical data

– The front panel of the FIRE ALARM BOARD is made of 5 mm

thick laminate, matt blue in color with white engraving

The rear of the Board is protected with a grey plastic cover.

representing the built-in function groups.

Its shape allows the Board to be placed at an ergonomically

favorable angle for example on a table.

The FIRE ALARM BOARD can be converted into a portable

training unit by simply screwing it into a Box: All the experiments

can be conducted directly in the Box. Dust-free storage

and protection against transport damages are further advantages

of the Box version.

Dimensions and weights

– FIRE ALARM BOARD (Type 2108):

532 x 297 x 120mm (wxhxd); weight: 3.0 kg

– Box version, consisting of:

FIRE ALARM BOARD (Type 2108) and Box (Type 2107.20):

580 x 450 x 155mm; total weight: 6.2 kg