Açıklama
INTERNAL COMPONENTS
———————————
● 2 Thermo – Differential Alarms (Infrared)
● Smoke Alarm
● Manual Alarm
● Main Alarm Connected to Fire Station
● Keystore
● Indoor and Outdoor Horn
● Optical Alarm Warning (with LEDs)
● 4 Resistor Terminators
● Fire Alarm Center:
Key-Operating Switch for Locking Fire Alarm to Master Alarm
Inputs: LINE 1 / LINE 2 / Door Position / Switch Position / Answer
Outputs: ALARM OUTPUT / Relay K1 / 12 V External / Door Opener
Indicators (with LEDs): Operation ON, Operation OFF / ALARM / FAULT / FAULT OFF,
ALARM for LINE 1 and LINE 2/ Locked Key Store / Key Store Location
Buttons: BUZZER OFF / RESET /OFF, ON for LINE 1 and LINE 2
Simulation: Power Failure and Battery Loss
EXPERIMENTS THAT CAN BE DONE AND THE SUBJECTS THAT CAN BE EXPLAINED FROM THE EXPERIMENT BOOK;
—————————————————————- —————————————————————- ———
● VdS/TSE Rules
● Fire Alarm System Components
●Smoke Alarms
● EXPERIMENTS THAT CAN BE DONE AND THE SUBJECTS THAT CAN BE EXPLAINED FROM THE EXPERIMENT BOOK;
● Flame Detection
● Non-Automatic Fire Alarms
● Network Alarm
● Thermal Difference Alarms
● Optical Smoke Alarms
● Button Fire Alarm
● Fire Service Private Warehouse
● Fire Gas Alarm
● Temperature Alarm
● Thermal Alarms
Technical Data
——————-
Mains connection
– Mains voltage: 230 V AC / 115 V AC (110 V AC)
50 … 60 Hz; approx. 10VA
Thermo-differential alarm (infrared)
– Operating voltage: 12 V DC
Optical smoke alarm
– Operating voltage: 12V
hand alarm
– The glass pane is simulated by a sliding plexiglass door.
– The alarm is indicated by a red LED.
– The alarm is triggered by a pushbutton.
– Operating voltage: 12 V
Main alarm
– The alarm is indicated by a red LED.
– Main alarm at rest, green LED alight
– The alarm is triggered by a pushbutton.
– Alarm to fire station additionally indicated by a red LED
– Operating voltage: 12 V
Alarm center:
– Voltage output: 12 V DC / 0.2 A
All inputs and outputs are wired by 2 mm jacks.
Mechanical data
– The front panel of the FIRE ALARM BOARD is made of 5 mm
thick laminate, matt blue in color with white engraving
The rear of the Board is protected with a grey plastic cover.
representing the built-in function groups.
Its shape allows the Board to be placed at an ergonomically
favorable angle for example on a table.
The FIRE ALARM BOARD can be converted into a portable
training unit by simply screwing it into a Box: All the experiments
can be conducted directly in the Box. Dust-free storage
and protection against transport damages are further advantages
of the Box version.
Dimensions and weights
– FIRE ALARM BOARD (Type 2108):
532 x 297 x 120mm (wxhxd); weight: 3.0 kg
– Box version, consisting of:
FIRE ALARM BOARD (Type 2108) and Box (Type 2107.20):
580 x 450 x 155mm; total weight: 6.2 kg